SYNPour 100

SYNPour 100 is a 1-component, solvent-free, straight MDI polyurethane prepolymer with enhanced UV stability.

CALL FOR AVAILABILITY

SKU: POUR1 Category: Tag:

SYNPour 100

SYNPour™ 100 is designed for binding EPDM rubber granules in the production of synthetic sport surfacing.

Features

  • Solvent Free
  • No VOC
  • One Component
  • Enhanced UV Stability

Safety Guidelines

Always wear the recommended personal protective equipment. Avoid contact with eyes, skin, and clothing. Adequate ventilation is required during the application process.

Storage & Packaging

SYNPour 100 should be kept dry and cool. Storage temperature should be between 5°C (40°F) and 66°C (150°F). Do not expose containers to open flame, excessive heat, or direct sunlight.

Product shelf life is 1 year in original sealed container.

SYNPour 100 is packaged at 20 kg (approximately 4.89 gallon), 210 kg (approximately 51 gallon), and 1050 kg (approximately 256 gallon).

Coverage

SYNPour 100 is ready to use as supplied and should be mixed with dry rubber granules as follows:

  • SYNPour 100 = 20% by weight
  • Rubber granules = 80% by weight

Installation Guidelines

Before application, the surface to be coated must be clean, dry, and free of oil, grease, dirt, and any foreign residue. The mixture can be applied with a trowel in order to obtain a uniform, level surface.

The cure time varies with temperature and humidity. High temperature and high humidity will decrease cure time, while low temperature and low humidity will increase cure time.

Limitations

  • Do not apply over wet or damp substrates
  • Substrate and application minimum temperature: 10°C (50°F)
  • Substrate and application maximum temperature: 40°C (104°F)
  • Permissible relative humidity: 40 – 90%

CALL FOR AVAILABILITY

Detailed
information

Renewable Content

1.64%

VOC Content

0 g/L*

Density

23°C (73°F)1.03 – 1.13 g/cm3

Color

Opaque/gold to light brown

Cure Time

20°C (68°F) / 50% Relative Humidity15 – 16 hours

*Based on

Standard formula calculation. Above figures are guide values and should not be used as a base for specifications. Consult the Safety Data Sheet for more details.

Reviews

Be the first to review “SYNPour 100”